Add to Cart
Performing a successful calibration has never been so simple:
Most measuring issues are due to incorrect calibration procedures. With our illustrated, step-by-step on-screen calibration and troubleshooting procedures, water quality professionals can succeed every time.
Sensors designed for every application:
We offer standard laboratory and rugged field IntelliCALⓇ smart sensors available with the HQ Series to measure a wide variety of parameters including Total Dissolved Solids (TDS), Optical Dissolved Oxygen (DO), Biochemical Oxygen Demand (BOD), Temperature, Conductivity, and pH. IntelliCAL smart probes are automatically recognized by HQ meters, retain calibration history and method settings to minimize errors and setup time. They incorporate proven technology to deliver superior accuracy and response times – even when measuring challenging samples or challenging operating environments.
Accessories Included | USB charger, power cable, and clips |
Automatic Buffer Recognition | Yes |
Backlight | Yes |
Barometric Pressure Measurement | Automatic compensation of DO when using an LDO or LBOD probe |
Calibration | Demal (1D/ 0.1D/ 0.01D); Molar (0.1M/ 0.01M/0.001M); NaCl (0.05%; 25µS/cm; 1000µS/cm; 18mS/cm); Standard sea water; User defined |
Calibration Intervals/Alerts/Reminder | Off, selectable from 2 hours to 7 days |
Certifications | CE, FCC, ISED, RCM, KC, ETL Verified: US DOE/ NRCan Energy Efficiency, RoHS |
Conductivity Measurement Range | Yes |
Custom Calibration Standards | Yes |
Data Export | USB connection to PC or USB storage device (limited to the storage device capacity). |
Data Memory | 10,000 data points |
Data Storage | Automatic in Press to Read Mode and Interval Mode. Manual in Continuous Read Mode. |
Dimensions (H x W x D) | 63 mm x 97 mm x 220 mm |
Display | Up to 3 parameters at a time, dependent on HQ model |
Display Type | 536x336 Mono-TFT |
DO Measurement Range | 0.1 - 20.0 mg/L (ppm), 1 - 200% saturation |
DO Resolution | 0.1 |
Enclosure Rating | IP67 (with battery compartment installed) |
GLP Features | Date; Time; Sample ID; Operator ID, Calibration |
Inputs | 1 |
Instrument | Portable |
ISE Direct Measurement Range | No |
ISE Electrode Calibration | No |
Kit? | Meter only |
Languages | English, Chinese - Simplified, Spanish, French, German, Italian, Japanese, Turkish, Dutch, Portuguese (PT & BR), Korean, Danish, Swedish, Polish, Norwegian, Hungarian, Greek, Finnish, Czech, Romanian, Croatian, Bulgarian, Slovak, Lithuanian, Estonian, Slovenian, Russian |
Lock Function | Continuous / Auto-stabilization ("press to read") / At Interval |
Measurement Method | Probe specific programmed method settings |
Model | HQ2100 Multi/1 Channel |
mV Measurement at Stable Reading | Yes |
mV Measurement Range | Yes |
mV Resolution | 0.1 mV |
Operating Error Messages | Clear text error messages displayed |
Operating Humidity | 90% (non-condensing) |
Operating Interface | Soft Touch Keypad |
Operating Temperature | 0 - 60 °C |
ORP Electrode Calibration | Predefined ORP standards (including Zobell's solution) |
Parameter | pH, Conductivity, TDS, Salinity, Dissolved Oxygen (DO), ORP |
pH Buffer Sets | Colour-coded: 4.01, 7.00, 10.01 pH; IUPAC: 1.679, 4.005, 7.000, 10.012, 12.45 DIN: 1.09, 4.65, 9.23 User-defined custom buffer sets |
pH Electrode calibration | 1 - 3 Calibration points Calibration summary data logged and displayed |
pH Measurement Range | 0 - 14 pH |
pH Resolution | Selectable: 0.001/0.01/0.1 pH |
Power Supply | Rechargeable lithium-ion battery 18650 (internal) Class II, USB power adapter: 100 - 240 VAC, 50/60 Hz input; 5 VDC at 2 A USB power adapter output (external) |
Probe Type | Intellical Standard Laboratory or Rugged Field |
Probes included | None |
Protection Class | IEC Class III (SELV (Separated/Safety Extra-Low Voltage) powered); external |
Salinity Measurement Range | 0 - 42 (ppt) (‰) |
Salinity Resolution | 0.01 (ppt) (‰) |
Sensor A | None |
Sensor B | None |
Sensor C | None |
Storage Conditions | -20 - 60 °C, max. 90% relative humidity (non-condensing) |
TDS Measurement Range | 0.00 mg/L - 50.0 g/L NaCl |
TDS Resolution | 0.01 mg/L - 0.1 g/L upon measuring range |
Temperature Compensation | Automatic Temperature compensation for pH |
Temperature Measurement | °C or °F |
Temperature Resolution | 0.1 °C |
Type of measurement | Field Measurements |
Weight | 519 g (Meter only) |
What's included? | HQ2100 Portable pH/ORP/EC/TDS/DO Multi-Meter, 1 channel, includes manuals, Li-Ion batteries, USB charger with cable for USA. |