18 in 1 Multi Gas Detector

Ask Latest Price
Video Channel
Brand Name :HiYi
Model Number :PTM600
Certification :CE/RoHS
Place of Origin :China
MOQ :1
Price :USD 1000-10000/pcs
Payment Terms :T/T, Western Union, MoneyGram
Supply Ability :10000 set/month
Delivery Time :3-7 days
Packaging Details :alloy case
Name :CO H2S O2 O3 CH4 CO2 NH3 PM2.5 Cl2 HCl Built-in Printer ATEX 18 in 1 Multi Gas Detector
Gas Type :up to 18
Data Storage :100, 000 entries
Display :3.5-inch TFT LCD display
Response Time :<20s
Output Signal :Wireless transmission and print function(Optional)
Working Environment :-40 ℃ ~ 70 ℃, <95% RH (no dew)
Battery :3.6V Li-on battery, 10000 mA
Charging Time :8 hours
Protection Level :IP66
Alarm Mode :Audible-visual alarm,Vibration alarm,Voice≥75dB@25cm
Size :23* 21*120 cm
Weight :2.5 Kg
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

HiYi CO H2S O2 O3 CH4 CO2 NH3 PM2.5 Cl2 HCl Built-in Printer ATEX 18 in 1 Multi Gas Detector

HiYi PTM600 Portable Gas Detector


18 in 1 | Internal Pump | Built-in Printer | Wireless Data Transmission


OVERVIEW


PTM600 portable gas detector has the function of measuring multi gases, temperature and humidity.


The product is provided with high measurement precision, stable performance and simple operation and convenient to carry.
It is possible to simultaneously detect 1 ~6 types of gases, up to 18 or more types of gases, and the types for detection are more than 500 types.

18 in 1 Multi Gas Detector

FEATURES & BENEFITS

1.Fast and Effecient Gas Detection

  • It is possible to simultaneously detect 1 ~ 6 types of gases, whichcan be expanded to 18 or more, and the types for detection are more than 500 types. It is suitable for detecting the concentrations of gases in the atmosphere environment in the pipeline or confined space; and the purity of the gas leakage and various high concentration single gases with the background gas as nitrogen gas or oxygen gas.
  • There are 7 gas units to display, and the units can be switched freely. Units that can be selected: PPM, mg/m3, Vol%, LEL%, PPHM, ppb, mg/l.

2.Richa Human-machine Interface

  • 3.5-inch high-definition color screen, display the information such as real-time concentration, alarm, time, temperature, humidity, storage, and so on; the menu interface adopted high definition simulation graphics to display the function name of each menu.
  • Graphical display, and use the form of curve to reflect the trend of gas concentration changes in a certain period of time.
  • Simultaneously display the concentrations of five types of gases, repeatedly display the concentration of single-channel gases in large font, and display the real-time curve. And it is possible to switch among three display modes.

3.Multi Gas Detection Mode and Large Data Storage

  • Standard configuration is the data storage capacity for 100, 000 entries; real-time storage and fixed time storage are supported, or only the data of the alarm concentration will be stored. Large capacity can be customized.
  • It is supported to use the local host to view, and delete data, and upload the data via USB, RS232 interface or infrared communication to the computer for data analysis or printing.

4.Multi Alarm Modes and Data Logging Function

  • 0.4 meter stainless steel sampling handle (with dust filter, not retractable) ,preliminary treatment of the detection gas, so as to protect the equipment.
  • Multiple alarm modes, and multi-directional and three-dimensional indication alarm states. It includes sound & light alarm, vibration alarm, display screen visual alarm.Alarm types include: concentration alarm, under-voltage alarm, and failure alarm.
  • Multiple alarm mode settings: low alarm, high alarm, interval alarm, and weighted average alarm.
  • Zero-point automatic tracking; long-term use will not be affected by the zero drift.
  • Multi-level calibration for target points, can ensure the linearity and accuracy of the measurements.
  • Log recording Record the calibration logs, repair logs, failure history, failure countermeasure solutions, sensor service life due reminder, and function of reminder for the time of next concentration calibration.
  • Data recovery function; in case of mis-operation, it is possible to select partial or full recovery.
  • Mis-operation recognition function: automatic recognition and prevention of the concentration calibration mis-operation, which is possible to avoid the poor performance that may be caused by human factors.

5.Temperature and humidity measurement function

  • 1.2 m retractable sampling handle (1-10 meter hose, and the standard length is 1 meter)
  • High temperature sampling and cooling filter handle
  • High temperature humidity pretreatment system· External remote sampling pump
  • Multiple humidity dust filter· CD-ROM (upper level computer communication software)
  • SD card storage
  • USB disk storage
  • External mini wireless infrared printer
  • Built-in mini printer
  • Wireless data communications: RS232, infrared communication, automatic recognition

18 in 1 Multi Gas Detector

18 in 1 Multi Gas Detector18 in 1 Multi Gas Detector

SPECIFICATION

Gases to be detected
Arbitrary combination of 1 ~ 6 types of gases which can be expanded to 18 or more types of gases, such as toxic gases, oxygen gas, carbon dioxide, inflammable and explosive gases, TVOC, and so on.
Optional configuration: temperature and humidity measurements.
Application scenarios
All the cases which requires the portable rapid detection of gas concentrations such as petroleum, chemical, pharmaceutical,
environmental protection, combustion gas distribution, warehousing, smoke gas analysis, air governance, and so on.
Detection range
0 ~ 1, 10, 100, 1000, 5000, 50000, 100000ppm, 200 mg/L, 100%LEL, 20%, 50%, 100%Vol, can be selected; and other ranges can be customized.
Resolution
0.01ppm or 0.001ppm (0 ~ 10 ppm);
0.01ppm (0 ~ 100 ppm),
0.1ppm (0 ~ 1000 ppm),
1ppm (0 ~ 10000 ppm or more),
0.01 mg/l (0 ~ 200 mg/l),
0.1% LEL,
0.01%,
0.001% Vol
Detection principle
Electrochemical, catalytic combustion, infrared, thermal conductivity, PID photoionization, and so on, depending on the type of gas, range, field environment and user demand.
Sensor service life
Electrochemical principle: 2 ~ 3 years; Oxygen gas: 2 years or 6 years can be selected; infrared principle: 5 ~ 10 years;
catalytic combustion: 3 years; thermal conductivity: 5 years; PID photoionization: 2 ~ 3 years.
Allowable error
≤±2% F.S (other or higher precision levels can be customized)
Linearity
≤±2%
Repeatability
≤±2%
Uncertainty
≤±2%
Response time
T90≤20 seconds
Recovery time
≤30 seconds
Working environment
Temperature: -40 ℃ ~ + 70 ℃, humidity: ≤10 ~ 95% RH, and built-in filters can be used in high humidity or high dust environment.
Sample gas temperature
-40 ℃ ~ + 70 ℃, and the optional configuration of high-temperature sampling and cooling filter handle will be possible to detect the smoke gas at the temperature of 1300 ℃.
Temperature and humidity measurement
Optional configuration: temperature at -40 ℃ ~ + 70 ℃, accuracy level at 0.5 ℃; humidity at 0 ~ 100% RH, precision level at 3 % RH
Power supply
3.6VDC, 10000mA high capacity rechargeable polymer battery
Display mode
3.5-inch high-definition color screen
Detection mode
Built-in pump-suction type measurement, and flow rate at 800 ml / min. Calibration flow rate should be greater than 800 ml / min,
three-way pipe should be connected, so as to ensure that the excessive gas will be discharged from the bypass
Alarm mode
It is possible to set as sound & light alarm, vibration alarm, turning off the alarm.
Communication interface
USB (charging and communication), optional: RS232, infrared communication, automatic recognition
Data storage
Standard configuration is the data storage capacity for 100, 000 entries; SD card storage and USB disk storage functions are optional configuration.
Protection level
IP66
Explosion-proof type
Intrinsically safe type
Explosion-proof mark
Exia II CT6
Exterior dimensions
230×210×120 mm (L×H×W)
Weight
2.5Kg
Standard accessories
Manual, qualification certificate, warranty card, USB charger (including the data cable), high-grade aluminum instrument case,
built-in humidity dust filter, 0.4 meter stainless steel sampling handle (1 meter of hose, with dust filter, not retractable)
Optional items
Temperature and humidity measurement function, 1.2 m retractable sampling handle (1-10 meter hose, and the standard length is 1
meter), external remote sampling pump, high temperature sampling and cooling filter handle, high temperature humidity pretreatment
system, CD-ROM (upper level computer communication software), external mini wireless infrared printer, built-in mini printer, SD
card storage, USB disk storage, wireless data communications.

APPLICATION


All the cases which requires the portable rapid detection of gas concentrations such as petroleum, chemical, pharmaceutical, environmental protection, combustion gas distribution, warehousing, smoke gas analysis, air governance, and so on.

18 in 1 Multi Gas Detector